Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 43
Filtrar
1.
Arq Bras Cardiol ; 120(1): e20220892, 2023 01 23.
Artigo em Inglês, Português | MEDLINE | ID: mdl-36700596
2.
Arq. bras. cardiol ; 120(1): e20220892, 2023. tab, graf
Artigo em Português | LILACS, CONASS, Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1420149
4.
RELAMPA, Rev. Lat.-Am. Marcapasso Arritm ; 30(1): 3-8, jan.-mar. 2017. ilus, graf
Artigo em Português | LILACS, Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-837227

RESUMO

Introdução: Este trabalho teve por objetivos identificar as características comuns aos geradores e classificá-los no menor número possível de grupos para facilitar a identificação radiológica, e, também, identificar características que permitam diferenciar geradores DF1 de DF4. Método: A amostragem foi composta por 62 imagens de geradores de dispositivos implantáveis bem como de cabos-eletrodos comercialmente disponíveis no Brasil de 2008 até o presente momento das empresas Biotronik, Medtronic, St. Jude Medical e Boston Scientific. As imagens consideradas com qualidade adequada de cada modelo de dispositivo implantável foram selecionadas em busca de características comuns a cada fabricante. Resultados: A revisão criteriosa das características de cada fabricante e modelo possibilitou divisar claramente oito categorias, com características únicas de cada fabricante para estimuladores (grupo 1) e cardiodesfibriladores (grupo 2). Um algoritmo de identificação foi desenvolvido, a partir das características mais facilmente identificáveis de cada grupo. Conclusão: A identificação radiológica dos dispositivos implantáveis é possível e confiável. Os cabos-eletrodos de mesma função (choque ou estimulação) não puderam ser diferenciados em relação ao fabricante, mas algumas características das conexões de cabos-eletrodos de choque podem diferenciar a conexão DF1 de DF4, bem como mono coil de duplo coil


Background: This study is aimed at identifying common characteristics of generators and classify them into the lowest possible number of groups to facilitate X-ray identification as well as to identify characteristics to differentiate DF1 and DF4 generators. Method: The sample included 62 images of implantable device generators and leads available in the Brazilian market from 2008 to the present moment manufactured by Biotronik, Medtronic, St. Jude Medical and Boston Scientific. Good quality images from each implantable device model were chosen to help identify common characteristics of each manufacturer. Results: A careful review of manufacturer's characteristics and model enabled a clear division into eight categories with each manufacturer's unique characteristics for pacers (group 1) and cardiac defibrillators (group 2). An identification algorhythm was developed based on the most easily identifiable characteristics of each group. Conclusion: X-ray identification of implantable devices is possible and reliable. Leads with the same function (shock or pacing) were not differentiated by manufacturer, but some shock lead connection characteristics may differentiate DF1 from DF4 connections, as well monocoil from double coil


Assuntos
Humanos , Raios X , Radiografia/métodos , Desfibriladores Implantáveis/tendências , Marca-Passo Artificial , Eletrodos/normas , Dispositivos de Terapia de Ressincronização Cardíaca/tendências , Indústrias/normas
5.
Barueri; Manole; 2017. 462 p. ilus.
Monografia em Português | Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1084059
6.
RELAMPA, Rev. Lat.-Am. Marcapasso Arritm ; 29(1): 3-11, jan.-mar.2016. graf
Artigo em Português | LILACS, Sec. Est. Saúde SP | ID: lil-788818

RESUMO

Desde que foi iniciado, há 25 anos, o Registro Brasileiro de Marcapassos, Desfibriladores e Ressincronizadores Cardíacos (RBM) cadastrou 306.886 cirurgias até 31 de dezembro de 2014, das quais 216.537 foram primeiro implante (190.747 marcapassos, 13.725 cardiodesfibriladores, 6.683 ressincronizadores, 4.052 cardiodesfibriladores com ressincronizadores e 1.330 sem informações) e 90.349, trocas de dispositivos. Método: Analisamos o número de cirurgias e suas variedades entre 2000 e 2014 (dados de 31 de dezembro de 2015) e comparamos com alguns países, com a média europeia e com informações populacionais do Instituto Brasileiro de Geografia e Estatística. Resultados: O número do RBM referente às cirurgias realizadas no Brasil (129/1.000.000) foi comparado com a média europeia (960/1.000.000), verificando-se valores 7,4 vezes menores (mesmo estimando-se proporcionalmente, os valores são 4,5 vezes menores). A modificação na etiologia da primeira cirurgia entre 2009 e 2014 revelou aumento da incidência de fibrose do sistema de condução (de 32,58% para 38,05%) e redução da doença de Chagas (de 18% para 11,70%), sem grandes modificações nas outras causas. Considerando-se o número total de cirurgias, nota-se pequeno aumento em todas as regiões, exceto a Norte, com discreto aumento das cirurgias de cardiodesfibrilador implantável e cardiodesfibrilador implantável multissítio em todo o País. Houve pequeno aumento dos hospitais que realizaram cirurgias com a utilização desses dispositivos. O número total de médicos que fazem implantes de dispositivos aumentou discretamente, especialmente nas regiões Sul e Sudeste, com queda discreta nas outras. O grupo que realizou até 10 cirurgias por ano cresceu 19,28% e o de 11-50 cirurgias por ano, 12,84%...


Since it was started, 25 years ago, the Brazilian Registry of Pacemakers, CardioverterDefibrillators,and Cardiac Resynchronization Therapy Devices (RBM) registered 306,886 surgeries by December 31, 2014, 216,537 of which were: first implant (190,747 pacemakers, 13,725 cardioverter-defibrillators, 6,683 cardiac resynchronization therapy devices, 4,052 cardioverter-defibrillators with cardiac resynchronization therapy devices, and 1,330 with no information) in addition to 90,349 device replacements. Method: We analyzed the number of surgeries and their varieties, mostly between 2000 and 2014 (data of December 31, 2015)and compared with some countries, with the European average and with populational information from the Instituto Brasileiro de Geografia e Estatística. Results: We compared the RBM number of surgeries perfomed in Brazil (129/1,000,000) with the European average (960/1,000,000) and noticed values 7.4 times lower (even when estimated proportionally, results were 4.5 times lower). The change in the etiology of first surgery between 2009 and 2014 revealed an increase in the incidence of fibrosis of the conduction system (from 32.58% to 38.05%), and reduction of Chagas disease (from 18% to 11.70%) without any major changes in other causes. When taking into account the total number of surgeries, a small increase was observed in all regions, except for the North, with a discrete increase of implantable cardioverter-defibrillators and multisite implantable cardioverter-defibrillators surgeries across the country. There was a small increase in the number of hospitals that perform surgeries using these devices. The total number of doctors that perform device implantations has increased slightly, especially in the South and Southeast regions, with a slight decrease in the other regions. The group performing up to 10 surgeries per year increased 19.28%, and the one performing 11 to 50 surgeries per year increased 12.84%...


Assuntos
Humanos , Masculino , Feminino , Idoso , Brasil , Estimulação Cardíaca Artificial/métodos , Marca-Passo Artificial , Arritmias Cardíacas/terapia , Dispositivos de Terapia de Ressincronização Cardíaca , Doença de Chagas/etiologia , Doença de Chagas/terapia , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/terapia
10.
RELAMPA, Rev. Lat.-Am. Marcapasso Arritm ; 27(2): 94-105, abr.-jun.2014.
Artigo em Português | LILACS | ID: lil-727489

RESUMO

O implante de cardiodesfibriladores automáticos surgiu na década de 1980 como tratamentoalternativo na prevenção de arritmias graves em pacientes sobreviventes de fibrilação ventricular ou taquicardiaventricular sintomática. Os resultados iniciais mostraram resultados favoráveis à prevenção de morte súbita eredução de mortalidade geral com o uso desses dispositivos. Diante disso, a comprovação dessas evidências porestudos randomizados tornou-se de suma importância para indicação dessa prótese. A revisão dos resultadosdesses estudos demonstrou que o implante de cardiodesfibrilador automático éprimeira opção na terapêuticade pacientes com taquicardia ventricular sustentada ou fibrilação ventricular com comprometimentohemodinâmico, sendo também superior ao tratamento farmacológico em pacientes com taquicardia ventricularsustentada sintomática ou após ressuscitação de parada cardiorrespiratória. Nos casos de doença arterialcoronária, disfunção ventricular esquerda e presença de potenciais tardios ao eletrocardiograma, não háevidências em favor do implante desse dispositivo. O implante profilático de cardiodesfibrilador implantável empacientes de alto risco com infarto agudo do miocárdio recente não reduz a mortalidade geral. Esse dispositivonão representa benefícios para a sobrevivência nos casos de cardiomiopatia dilatada idiopática. A terapia comcardiodesfibrilador implantável combinada à terapia de ressincronização cardíaca melhora a qualidade devida, a classe funcional e a capacidade física na insuficiência cardíaca moderada a grave. Esse dispositivo estáassociado a redução equivalente da mortalidade em idosos e em indivíduos mais jovens, sem comprometimentoda qualidade de vida nos idosos, excluindo-se pacientes com comorbidades graves. O objetivo deste artigo érevisar os principais estudos clínicos em cardiodesfibrilador implantável, avaliando aspectos essenciais paraindicação dessa terapêutica.


The implantation of implantable cardioverter-defibrillators emerged in the 1980s as an alternativetreatment in the prevention of serious arrhythmias in survivors of ventricular fibrillation or symptomatic ventriculartachycardia. Initial results showed favorable for prevention of sudden death and overall mortality reduction withimplantable cardioverter-defibrillator results. Therefore, the evidence of such evidence by randomized trials hasbecome of paramount importance for implantable cardioverter-defibrillator indication. A review of the results of hese studies demonstrated that implantable cardioverter-defibrillator implantation is first choice in the treatmentof patients with sustained ventricular tachycardia or ventricular fibrillation with hemodynamic compromise,being also superior to medical therapy in patients with symptomatic sustained ventricular tachycardia or afterresuscitation from cardiac arrest. In cases of coronary artery disease, left ventricular dysfunction and presenceof late potentials on electrocardiogram, there is no evidence in favor of implantable cardioverter-defibrillatorimplantation. Prophylactic implantable cardioverter-defibrillator implantation in high-risk patients with recentacute myocardial infarction does not reduce overall mortality. The implantable cardioverter-defibrillator doesnot represent benefits for survival in cases of idiopathic dilated cardiomyopathy. Combination therapy withimplantable cardioverter-defibrillator and cardiac resynchronization therapy improves quality of life, functionalclass and exercise capacity in moderate to severe heart failure. The implantable cardioverter-defibrillator isassociated with an equivalent reduction of mortality in elderly and younger subjects without impairment ofquality of life in elderly patients, excluding patients with severe comorbidities.


Assuntos
Humanos , Adulto Jovem , Idoso , Arritmias Cardíacas/complicações , Insuficiência Cardíaca/diagnóstico , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Ensaio Clínico , Medicina Baseada em Evidências , Estimulação Cardíaca Artificial/métodos
12.
In. Pachón Mateos, José Carlos; Pachón Mateos, Enrique Indalécio. Marca-passos, desfibriladores e ressincronizadores cardíacos: noções fundamentais para o clínico. São Paulo, Atheneu, 2014. p.1-15, ilus.
Monografia em Português | Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1084236
14.
RELAMPA, Rev. Lat.-Am. Marcapasso Arritm ; 26(3): 151-161, jul.-set. 2013. tab
Artigo em Português | LILACS | ID: lil-716124

RESUMO

A terapia de ressincronização cardíaca (TRC) surgiu como modalidade terapêutica para pacientes com insuficiência cardíaca (IC) refratária ao tratamento farmacológico. Ao longo dos últimos 15 anos, vários estudos clínicos buscaram estabelecer seus benefícios em diferentes populações. A revisão dos resultados desses estudos demonstrou que em pacientes com IC avançada (classe funcional III-IV da New York Heart Association - NYHA) a TRC produz melhorias consistentes para qualidade de vida, classe funcional e capacidade de exercício, além de reduzir as hospitalizações e a taxa de mortalidade. Esses efeitos benéficos são decorrentes do remodelamento reverso do ventrículo esquerdo, com melhoria da função ventricular. Em relação aos pacientes com IC leve a moderada (classe funcional I-II da NYHA), os resultados são controversos, embora a maioria dos estudos tenha demonstrado efeitos benéficos da TRC. Em pacientes com fibrilação atrial, existem poucos estudos bem delineados publicados, mas os resultados são favoráveis à TRC. Até 50% dos pacientes submetidos à TRC evoluem como não respondedores e a identificação destes pacientes é um desafio. Dessa maneira, várias questões ainda precisam ser elucidadas, particularmente os critérios preditivos da resposta à TRC e os benefícios da TRC nos pacientes com IC discreta, fibrilação atrial e outras arritmias. O objetivo deste artigo é revisar os principais estudos clínicos em TRC, abordando aspectos inerentes a essa modalidade terapêutica.


Assuntos
Humanos , Masculino , Feminino , Insuficiência Cardíaca , Ensaios Clínicos Controlados Aleatórios como Assunto , Terapia de Ressincronização Cardíaca/métodos , Tratamento Farmacológico , Ecocardiografia/métodos , Exercício Físico/fisiologia , Função Ventricular/fisiologia , Qualidade de Vida
15.
Rev Soc Bras Med Trop ; 45(3): 340-5, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22760133

RESUMO

INTRODUCTION: The septal position is an alternative site for cardiac pacing (CP) that is potentially less harmful to cardiac function. METHODS: Patients with Chagas disease without heart failure submitted to permanent pacemaker (PP) implantation at the Clinics Hospital of the Triângulo Mineiro Federal University (UFTM), were selected from February 2009 to February 2010. The parameters analyzed were ventricular remodeling, the degree of electromechanical dyssynchrony (DEM), exercise time and VO2 max during exercise testing (ET) and functional class (NYHA). Echocardiography was performed 24 to 48 h following implantation and after one year follow-up. The patients were submitted to ET one month postprocedure and at the end of one year. RESULTS: Thirty patients were included. Patient mean age was 59 ± 13 years-old. Indication for PP implantation was complete atrioventricular (AV) block in 22 (73.3%) patients and 2nd degree AV block in the other eight (26.7%). All patients were in NYHA I and no changes occurred in the ET parameters. No variations were detected in echocardiographic remodeling measurements. Intraventricular dyssynchrony was observed in 46.6% of cases and interventricular dyssynchrony in 33.3% of patients after one year. CONCLUSIONS: The findings of this work suggest that there is not significant morphological and functional cardiac change following pacemaker implantation in septal position in chagasic patients with normal left ventricular function after one year follow-up. Thus, patients may remain asymptomatic, presenting maintenance of functional capacity and no left ventricular remodeling.


Assuntos
Estimulação Cardíaca Artificial/métodos , Cardiomiopatia Chagásica/terapia , Marca-Passo Artificial , Adolescente , Adulto , Idoso , Ecocardiografia , Eletrocardiografia , Teste de Esforço , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento , Septo Interventricular , Adulto Jovem
16.
Rev. Soc. Bras. Med. Trop ; 45(3): 340-345, May-June 2012. ilus, graf, tab
Artigo em Inglês | LILACS | ID: lil-640432

RESUMO

INTRODUCTION: The septal position is an alternative site for cardiac pacing (CP) that is potentially less harmful to cardiac function. METHODS: Patients with Chagas disease without heart failure submitted to permanent pacemaker (PP) implantation at the Clinics Hospital of the Triângulo Mineiro Federal University (UFTM), were selected from February 2009 to February 2010. The parameters analyzed were ventricular remodeling, the degree of electromechanical dyssynchrony (DEM), exercise time and VO2 max during exercise testing (ET) and functional class (NYHA). Echocardiography was performed 24 to 48h following implantation and after one year follow-up. The patients were submitted to ET one month postprocedure and at the end of one year. RESULTS: Thirty patients were included. Patient mean age was 59±13 years-old. Indication for PP implantation was complete atrioventricular (AV) block in 22 (73.3%) patients and 2nd degree AV block in the other eight (26.7%). All patients were in NYHA I and no changes occurred in the ET parameters. No variations were detected in echocardiographic remodeling measurements. Intraventricular dyssynchrony was observed in 46.6% of cases and interventricular dyssynchrony in 33.3% of patients after one year. CONCLUSIONS: The findings of this work suggest that there is not significant morphological and functional cardiac change following pacemaker implantation in septal position in chagasic patients with normal left ventricular function after one year follow-up. Thus, patients may remain asymptomatic, presenting maintenance of functional capacity and no left ventricular remodeling.


INTRODUÇÃO:A posição septal representa um sítio alternativo de estimulação cardíaca artificial (ECA) potencialmente menos deletério para a função cardíaca. M ÉTODOS: Pacientes chagásicos sem insuficiência cardíaca submetidos a implante de marcapasso definitivo (MP) no Hospital de Clínicas da Universidade Federal do Triângulo Mineiro (UFTM) foram selecionados no período de fevereiro de 2009 a fevereiro de 2010. Os parâmetros analisados foram o remodelamento ventricular, o grau de dessincronia eletromecânica (DEM), tempo de exercício e VO2 máximo no teste ergométrico (TE) e a classe funcional (NYHA). O ecocardiograma foi realizado 24 a 48h após o implante e após um ano de seguimento. Os pacientes foram submetidos ao TE um mês após o procedimento e ao final de um ano. RESULTADOS: Foram incluídos 30 pacientes. A idade média foi de 59±13 anos. A indicação do implante de MP foi bloqueio atrioventricular (BAV) total em 22 (73,3%) pacientes e BAV do 2º grau nos outros 8 (26,7%). Todos os pacientes permaneceram em NYHA I e não houve mudança nos parâmetros do TE. Não foram detectadas variações nas medidas ecocardiográficas de remodelamento. Foi observada DEM intraventricular em 46,6% dos casos e interventricular em 33,3% dos pacientes ao final de um ano. CONCLUSÕES: Os achados deste trabalho sugerem que não houve mudanças morfológicas ou funcionais cardíacas significativas após o implante de marcapasso na posição septal em pacientes chagásicos com função ventricular esquerda normal após um ano de seguimento. Desta forma, os pacientes podem permanecer assintomáticos, com a manutenção da capacidade funcional e sem remodelamento ventricular esquerdo.


Assuntos
Adolescente , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem , Estimulação Cardíaca Artificial/métodos , Cardiomiopatia Chagásica/terapia , Marca-Passo Artificial , Ecocardiografia , Eletrocardiografia , Teste de Esforço , Seguimentos , Resultado do Tratamento , Septo Interventricular
17.
RELAMPA, Rev. Lat.-Am. Marcapasso Arritm ; 24(4): 271-276, out.-dez. 2011. tab, ilus
Artigo em Português | LILACS | ID: lil-610052

RESUMO

Com o advento da estimulação cardíaca artificial, surgiu a preocupação em expor seus princípios de maneira simples e prática. Em 1974, a Inter-Society Commission for Heart Disease Resources [ICHD] tomou essa iniciativa, ao desenvolver um código de três letras baseado no conceito sugerido por Nicholas P. D. Smyth, quatro anos antes. Ao longo dos anos, novos equipamentos cardio-estimuladores entraram no mercado, criando a necessidade de novas designações para as funções e os modos de operação, cada vez mais complexos. Em 1981, a revista PACE publicou a revisão do código ICHD, que passou a apresentar cinco letras. Outras nomenclaturas foram propostas pelo comitê composto por NASPE e BPEG, na tentativa de abranger dispositivos antibradicardia e antitaquicardia, por meio dos códigos NBG e NBD. Contradizendo todas as versões subsequentes ao código proposto por Nicholas Smyth, que objetivavam incluir o que de mais novo havia no assunto, foi proposta nova revisão do código NBG em 2002, que se mostra bastante simplificada e prática. Conclusão: A partir deste estudo, percebe-se que, independente das decisões dos fabricantes e do surgimento de novas tecnologias, o código de nomenclatura visa facilitar o entendimento das especificações dos dispositivos cardioestimuladores.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial
18.
RELAMPA, Rev. Lat.-Am. Marcapasso Arritm ; 24(4): 277-282, out.-dez. 2011. ilus
Artigo em Português | LILACS | ID: lil-610053

RESUMO

A síndrome de Twiddler é uma complicação rara relacionada aos dispositivos eletrônicos cardíacos implantáveis (DCEI). É caracterizada pela rotação do gerador de pulsos dentro da bolsa subcutânea, o que resulta em deslocamento dos cabos-eletrodos endocárdicos e disfunção do sistema. Relata-se o caso de uma paciente que apresentou perda de comando e sensibilidade nos canais atrial e ventricular na avaliação telemétrica ambulatorial, cinco meses após o implante de cardiodesfibrilador automático implantável com ressincronizador (CDI-R). Na reabordagem cirúrgica foi observado o deslocamento dos três cabos-eletrodos e seu enrolamento em torno do gerador, configurando a síndrome de Twiddler. Os cabos-eletrodos foram reposicionados nas câmaras direitas e o gerador fixado ao plano muscular nas duas extremidades para evitar recorrência do processo.


Assuntos
Humanos , Feminino , Pessoa de Meia-Idade , Bradicardia/complicações , Bradicardia/diagnóstico , Morte Súbita , Taquicardia/complicações , Taquicardia/diagnóstico , Ecocardiografia/métodos , Ecocardiografia , Radiografia Torácica
19.
Arq Bras Cardiol ; 96(1): 76-85, 2011 Jan.
Artigo em Inglês, Português, Espanhol | MEDLINE | ID: mdl-21308340

RESUMO

The conventional right ventricular stimulation can be associated with deleterious effects on cardiac function. The need for a more physiological artificial cardiac stimulation is undoubtedly one of the most important points in the area of cardiac electrotherapy. The programming algorithms for the maintenance of adequate atrioventricular conduction, the stimulation of alternative endocardial sites and the cardiac resynchronization therapy are used with the objective of attaining these goals. The stimulation of the bundle of His and the septal stimulation have been studied as alternative endocardial sites for the positioning of the electrode on the right ventricle. The septal stimulation represents a simple and practical alternative, with no additional costs involved and with potential benefits in decreasing the deleterious effects of the right ventricular stimulation. However, this alternative site involves a heterogeneous group of patients and presents conflicting results regarding its long-term clinical benefit. This article reviews the scientific evidence on the alternative sites for right ventricular stimulation, with emphasis on the safety of the procedure, the measurement of the electrophysiological parameters, assessment of the left ventricular function and the clinical follow-up of patients.


Assuntos
Terapia de Ressincronização Cardíaca/métodos , Fascículo Atrioventricular/fisiologia , Estimulação Cardíaca Artificial/efeitos adversos , Estimulação Cardíaca Artificial/métodos , Eletrocardiografia , Septos Cardíacos/fisiologia , Humanos , Radiografia , Volume Sistólico/fisiologia , Disfunção Ventricular Direita/diagnóstico por imagem , Disfunção Ventricular Direita/terapia
20.
Arq. bras. cardiol ; 96(1): 76-85, jan. 2011. ilus
Artigo em Português | LILACS | ID: lil-573608

RESUMO

A estimulação ventricular direita convencional pode estar associada a efeitos deletérios sobre a função cardíaca. A necessidade de uma estimulação cardíaca artificial mais fisiológica é, indiscutivelmente, um dos pontos mais importantes na área da eletroterapia cardíaca. Os algoritmos de programação para a manutenção da condução atrioventricular própria, a estimulação de sítios endocárdicos alternativos e a terapia de ressincronização cardíaca são utilizados com o intuito de alcançar este objetivo. A estimulação do feixe de His e a estimulação septal têm sido estudadas como sítios endocárdicos alternativos para o posicionamento do eletrodo no ventrículo direito. A estimulação septal representa uma alternativa simples, prática e sem custos adicionais e com potenciais benefícios na redução dos efeitos deletérios da estimulação do ventrículo direito. Entretanto, esse sítio alternativo envolve um grupo heterogêneo de pacientes e apresenta resultados conflitantes quanto ao seu benefício clínico a longo prazo. Este artigo faz uma revisão das evidências científicas sobre os sítios alternativos de estimulação ventricular direita, com ênfase na segurança do procedimento, na medida dos parâmetros eletrofisiológicos, na avaliação da função ventricular esquerda e no acompanhamento clínico dos pacientes.


The conventional right ventricular stimulation can be associated with deleterious effects on cardiac function. The need for a more physiological artificial cardiac stimulation is undoubtedly one of the most important points in the area of cardiac electrotherapy. The programming algorithms for the maintenance of adequate atrioventricular conduction, the stimulation of alternative endocardial sites and the cardiac resynchronization therapy are used with the objective of attaining these goals. The stimulation of the bundle of His and the septal stimulation have been studied as alternative endocardial sites for the positioning of the electrode on the right ventricle. The septal stimulation represents a simple and practical alternative, with no additional costs involved and with potential benefits in decreasing the deleterious effects of the right ventricular stimulation. However, this alternative site involves a heterogeneous group of patients and presents conflicting results regarding its long-term clinical benefit. This article reviews the scientific evidence on the alternative sites for right ventricular stimulation, with emphasis on the safety of the procedure, the measurement of the electrophysiological parameters, assessment of the left ventricular function and the clinical follow-up of patients.


La estimulación ventricular derecha convencional puede estar asociada a efectos deletéreos sobre la función cardíaca. La necesidad de una estimulación cardíaca artificial más fisiológica es, indiscutiblemente, uno de los puntos más importantes en el área de la electroterapia cardíaca. Los algoritmos de programación para la manutención de la conducción atrioventricular propia, la estimulación de sitios endocárdicos alternativos y la terapia de resincronización cardíaca son utilizados con el propósito de alcanzar este objetivo. La estimulación del haz de His y la estimulación septal han sido estudiadas como sitios endocárdicos alternativos para el posicionamiento del electrodo en el ventrículo derecho. La estimulación septal representa una alternativa simple, práctica y sin costos adicionales y con potenciales beneficios en la reducción de los efectos deletéreos de la estimulación del ventrículo derecho. Entre tanto, ese sitio alternativo envuelve un grupo heterogéneo de pacientes y presenta resultados conflictivos en cuanto a su beneficio clínico a largo plazo. Este artículo hace una revisión de las evidencias científicas sobre los sitios alternativos de estimulación ventricular derecha, con énfasis en la seguridad del procedimiento, en la medida de los parámetros electrofisiológicos, en la evaluación de la función ventricular izquierda y en el control clínico de los pacientes.


Assuntos
Humanos , Terapia de Ressincronização Cardíaca/métodos , Fascículo Atrioventricular/fisiologia , Estimulação Cardíaca Artificial/efeitos adversos , Estimulação Cardíaca Artificial/métodos , Eletrocardiografia , Septos Cardíacos/fisiologia , Volume Sistólico/fisiologia , Disfunção Ventricular Direita , Disfunção Ventricular Direita/terapia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...